01 POWER ISLAND / 01 CCPP / V. Ganapathy-Industrial Boilers and HRSG-Design (2003)
.pdf
may be found, and the ratio of actual to average heat flux should be computed. For the sake of illustration, use the following ratios of actual to average heat flux at the locations mentioned.
Distance from |
Ratio of actual to |
bottom (ft) |
average heat flux |
|
|
40 |
1.4 |
56 |
1.6 |
70 |
1.0 |
80 |
0.9 |
100 |
0.4 |
|
|
We must determine the maximum inside heat flux at each of the locations and correct it for flux inside the tubes to check for DNB. Hence, considering the tube OD=ID ratio of 1.19 and the 25% nonuniformity at each furnace elevation, we have the following local maximum inside heat flux at the locations mentioned ðqi is taken as qp d=diÞ :
Location (ft) |
qi (Btu=ft2 h) |
|
|
40 |
1.4 38,095 1.25 1.19 ¼ 79,335 |
56 |
90,440 |
70 |
56,525 |
80 |
50,872 |
100 |
22,600 |
|
|
It is desirable to obtain allowable quality of steam at each of these locations and check to be sure actual quality does not exceed it.
DNB tests based on particular tube profiles, roughness, and water quality as used in the operation give the most realistic data for checking furnace tube burnout. Correlations, though available in the literature, may give a completely wrong picture because they are based on tube size, heating pattern, water quality, and tube roughness that may not tally with actual operating conditions. However, they give the trend, which could be useful. For the sake of illustrating our example, let us use Fig. 7.10. This gives a good estimate only, because
Copyright © 2003 Marcel Dekker, Inc.
extrapolation must be carried out for the low heat flux in our case. We see the following trend at Gi ¼ 480,000 lb=ft2 h and 2700 psia:
Location (ft) |
Allowable quality (%) |
|
|
40 |
25 |
56 |
22 |
70 |
30 |
80 |
34 |
100 |
42 |
|
|
Figure 7.13 shows the actual quality (assuming linear variation, perhaps in reality quadratic) versus allowable quality. It shows that a large safety margin exists; hence, the design is safe. This exercise should be carried out at all loads (and for all circuits) before coming to a conclusion.
7.32a
Q:
How is the circulation system analyzed in fire tube boilers?
A:
The procedure is similar to that followed for water tube boilers in that the CR is assumed and the various losses are computed. If the losses associated with the assumed CR and the resulting mass flow are in balance with the available head, then the assumed CR is correct; otherwise another iteration is done. Because fire tube boilers in general use horizontal tubes, the allowable heat flux to avoid DNB is lower than when vertical tubes are used. With gas streams containing hydrogen and steam as in hydrogen plant waste heat boilers, the tube-side and hence the overall heat transfer coefficient and heat flux will be rather high compared to flue gas stream from combustion of fossil fuels. Typical allowable heat fluxes for horizontal tubes range from 100,000 to 150,000 Btu=ft2 h.
7.32b
Q:
Perform the circulation calculations for the system shown in Fig. 7.14 with the following data:
Steam flow ¼ 20;000 lb=h; |
steam pressure ¼ 400 psig |
Assume that saturated water enters the drum.
Copyright © 2003 Marcel Dekker, Inc.
FIGURE 7.13 Actual quality vs. allowable quality along furnace height.
Copyright © 2003 Marcel Dekker, Inc.
FIGURE 7.14 Circulation scheme in fire tube boiler.
A:
From steam tables, vf ¼ 0.194 and vg ¼ 1.12 cu ft=lb. Assume there are two downcomers of size 4 in schedule 40 (di ¼ 4.026 in.) and two risers of size 8 in schedule 40 (di ¼ 7.981 in.). The total developed length of each downcomer is 22.5 ft, and each has two 90 bends; the riser pipes have a total developed length of 5 ft. Exchanger diameter is 6 ft, and the center distance between the exchanger and the steam drum is 8 ft.
1.Assume CR ¼ 15; then
Mixture volume ¼ 0:067 1:12 þ 0:933 0:0194
¼ 0:0931
The head available due to the column of saturated water is 11=(0.0194 144) ¼ 3.94 psi, where 11 ft is the height of the water column.
2.Losses in downcomers:
a. |
Water velocity ¼ 0:05 15 |
20,000 |
|
||
|
|||||
2 |
|||||
|
|
0:0194 |
|
|
|
|
|
|
|
|
|
|
ð4:026Þ2 |
|
|
|
|
¼ 9 fps
Inlet plus exit losses ¼ 1:5 velocity head
9 ¼ 1:5 9 2 32 144 0:0194
¼ 0:68 psi
Copyright © 2003 Marcel Dekker, Inc.
b. Total |
developed |
length ¼ 22.5 þ 2 10 ¼ 42.5 ft, where 10 ft is |
||||||
the equivalent length of a 90 bend from Table 7.10. |
||||||||
DPf |
¼ 3:36 |
0:0165 15 |
20 |
|
2 |
|||
|
|
|
||||||
2 |
|
|||||||
|
|
0:0194 |
|
|
|
|
|
|
|
42:5 |
|
|
|
|
|
|
|
|
ð4:026Þ5 |
|
|
|
|
|
||
¼ 0:98 psi
where 0.0165 is the friction factor. Equation (13) was used for pressure drop of single-phase flow.
Total downcomer losses ¼ 0:68 þ 0:98
¼ 1:66 psi
3.Friction and acceleration losses in the exchanger may be neglected for this first trial, because in a fire tube boiler they will be negligible due to the low mass velocity.
4.Gravity losses in the exchanger: Using Fig. 7.7, r4 ¼ 0.57.
0:57
DPg ¼ 0:00695 6 0:0194 ¼ 1:22 psi
5.Gravity loss in riser pipe:
5 |
|
|
|
|
|
|
|
||
DPg ¼ |
|
|
|
¼ 0:37 psi |
|
|
|
|
|
0:0931 |
|
144 |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
6. Friction loss in riser: |
|
|
|
|
|
|
|
||
|
|
|
000 |
|
0:0931 |
|
|||
Velocity ¼ 0:05 15 |
20; |
|
|
|
¼ 11 fps |
||||
2 |
ð7:981Þ2 |
||||||||
Inlet plus exit losses ¼ 1:5 velocity head
1:5 11 11
¼ 2 32 0:0931 144 ¼ 0:21 psi
Friction loss ¼ 3:36 0:014 15 202 2
0:0931
5 ð7:981Þ5 ¼ 0:02 psi
where 5 ft is the developed length of the riser.
Copyright © 2003 Marcel Dekker, Inc.
Let the losses in drum internals ¼ 0.5 psi. This can vary depending on the type of internals used. Then
Total losses ¼ 1:66 þ 1:22 þ 0:37 þ 0:21 þ 0:02 þ 0:50 ¼ 3:98 psi
This is close to the available head; hence CR ¼ 15 is the circulation ratio for this system. The calculations can be fine-tuned with actual dimensions after the layout is done. One can compute the heat flux and compare it with the allowable heat flux to check if the circulation rate is adequate. Usually circulation is not a problem in this type of boiler, because the heat flux is low, on the order of 20,000–30,000 Btu=ft2 h, whereas the allowable flux could be 100,000– 150,000 Btu=ft2 h. See Chapter 8 for correlations for critical heat flux (CHF).
7.33
Q:
How is the flow in steam blowoff lines determined?
A:
Whenever steam flows to the atmosphere from a high pressure vessel, the flow reaches critical flow conditions, and beyond a certain pressure further lowering of pressure does not increase the steam discharge. The flow is given by the equation [17]
|
DP |
|
0:5 |
|
W ¼ 1891 Y d2 |
|
|
ð39Þ |
|
Kv |
||||
The value of DP to be chosen depends on K, the system resistance, where
K ¼ 12 f dLe
where
Le ¼ total equivalent length of all downstream piping including valves and fittings, ft
f ¼ Darcy friction factor
d ¼ pipe inner diameter, in.
Y ¼ expansion factor (see Table 7.13)
v ¼ specific volume of steam before expansion, cu ft=lb
DP ¼ pressure drop, lower of actual upstream pressure minus downstream pressure or that obtained from Table 7.13
Copyright © 2003 Marcel Dekker, Inc.
TABLE 7.13 Limiting Factors for Sonic
Velocity k ¼ 1.3
K |
D |
P=P0 |
Y |
|
1 |
|
|
|
|
|
|
1.2 |
0.525 |
0.612 |
|
1.5 |
0.550 |
0.631 |
|
2.0 |
0.593 |
0.635 |
|
3 |
0.642 |
0.658 |
|
4 |
0.678 |
0.670 |
|
6 |
0.722 |
0.685 |
|
8 |
0.750 |
0.698 |
|
10 |
0.773 |
0.705 |
|
15 |
0.807 |
0.718 |
|
20 |
0.831 |
0.718 |
|
40 |
0.877 |
0.718 |
|
100 |
0.920 |
0.718 |
|
|
|
|
|
Example
Determine the flow of saturated steam from a vessel at 170 psia to the atmosphere if the total equivalent system resistance K ¼ 10 and pipe inner diameter ¼ 2.067 in.
Solution. Specific volume of |
steam |
at 170 psia ¼ 2.674 ft3=lb. Actual |
DP ¼ 170 7 14.7 ¼ 155.3 psia. From |
Table |
7.13, for K ¼ 10, DP=P1 ¼ 0.773, |
or DP ¼ 170 0.773 ¼ 131.5 psia. Hence, use DP ¼ 131.5 psia. Also from Table 7.13 for K ¼ 10, Y ¼ 0.705. Hence
W ¼ 1891:0 0:705 ð2:067Þ2 |
|
10 2:674 |
|
0:5 |
|
||||
|
|
131:5 |
|
|
¼ 12;630 lb=h
7.34
Q:
How is the flow through boiler blowdown lines determined?
A:
Sizing of blowdown or drain lines is very important in boiler or process plant operations.
The problem of estimating the discharge rates from a boiler drum or vessel to the atmosphere or to a vessel at low pressures involves two-phase flow calculations and is a lengthy procedure [18].
Copyright © 2003 Marcel Dekker, Inc.
Presented below is a simplified approach to the problem that can save considerable time for engineers who are involved in sizing or estimating discharge rates from boiler drums, vessels, or similar applications involving water.
Several advantages are claimed for these charts, including the following.
No reference to steam tables is required. No trial-and-error procedure is involved. Effect of friction can be easily studied.
Obtaining pipe size to discharge a desired rate of fluid, the reverse problem, is simple.
Theory
The basic Bernoulli’s equation can be written as follows for flow in a piping system:
104v dp þ V 2 dk þ v dv þ dH ¼ 0 2g g
Substituting mass flow rate m ¼ V =v:
m2 |
dk þ 2 |
dv |
|
¼ 104 |
dP |
|
dH |
|
|
|
|
|
|
||||
2g |
v |
v |
v2 |
|||||
Integrating between conditions 1 and 2:
m2 |
|
v2 |
|
|
2 dP |
|
2 dH |
||||||
|
k þ 2 ln |
|
|
¼ 104 ð1 |
|
ð1 |
|
|
|
||||
2g |
v1 |
v |
v2 |
||||||||||
m ¼ |
2g |
|
|
104 |
2 |
|
dP |
||||||
|
ð1 |
|
|
|
|||||||||
k þ 2 lnðv2=v1Þ |
v |
||||||||||||
ð40Þ
ð41Þ
ð42aÞ
ð2 dH 1=2
1 v2
ð42bÞ
where K ¼ f l=d, the equivalent pipe resistance.
When the pressure of the vessel to which the blowdown pipe is connected is decreased, the flow rate increases until critical pressure is reached at the end of the pipe. Reducing the vessel pressure below critical pressure does not increase the flow rate.
If the vessel pressure is less than the critical pressure, critical flow conditions are reached and sonic flow results.
From thermodynamics, the sonic velocity can be shown to be
s
Vc ¼ v2 g |
dP |
104 |
ð43Þ |
|
|||
dv |
|||
|
|
s |
|
Copyright © 2003 Marcel Dekker, Inc.
and
¼ |
ss |
|||
|
|
|
|
|
mc |
100 g |
dP |
ð44Þ |
|
|
dv |
|||
The term ðdP=dvÞs refers to the change in pressure-to-volume ratio at critical flow conditions at constant entropy.
Hence, in order to estimate mc, Eqs. (42) and (44) have to be solved. This is an iterative procedure. For the sake of simplicity, the term involving the height differences will be neglected. For high pressure systems the error in neglecting this term is marginal, on the order of 5%.
The problem is, then, given K and Ps, to estimate Pc and m. This is a trial- and-error procedure, and the steps are outlined below, followed by an example. Figs. 7.16 and 7.17 are two charts that can be used for quick sizing purposes.
1.Assume a value for Pc.
2.Calculate ðdP=dvÞs at Pc for constant-entropy conditions. The volume change corresponding to 2–3% of Pc can be calculated, and then ðdP=dvÞs can be obtained.
3.Calculate mc using Eq. (44).
4.Solve Eq. (42b) for m.
|
2 |
dP |
|
|
Ð |
|
|
2 |
|
|
|
|
|
The term 10 4 |
|
12 dP=v is computed as follows using Simpson’s rule: |
|||||||||||
104 |
ð1 |
|
¼ 104 |
ð1 |
r dP |
|
|
|
|||||
v |
|
|
|
||||||||||
|
|
¼ |
Ps Pc |
ðrs þ |
4 |
rm þ rcÞ |
|||||||
|
|
|
|
6 |
|
|
|||||||
where rm ¼ density at a mean pressure of ðPs þ PcÞ=2. |
|||||||||||||
The densities |
are |
computed |
as |
isenthalpic conditions. The term 2 ln |
|||||||||
ðv2=v1Þ ¼ 2 ln ðrs=rcÞ is then found.
Then m is computed using Eq. (42b). If the m values computed using Eqs. (42b) and (44) tally, then the assumed Pc and the resultant mc are correct. Otherwise Pc has to be changed, and all steps have to be repeated until m and mc agree.
Example
A boiler drum blowdown line is connected to a tank set at 8 atm. Drum pressure is 100 atm, and the resistance K of the blowdown line is 80. Estimate the critical mass flow rate mc and the critical pressure Pc.
The procedure will be detailed for an assumed pressure Pc |
of 40 atm. |
||||||
3 |
s ¼ |
3 |
¼ |
0.7983 kcal=kg C; h |
l |
¼ |
334 kcal=kg, |
For steam |
table P |
100 atm, s |
|
|
|
||
vl ¼ 0.001445 m =kg, or r ¼ 692 kg=m .
Copyright © 2003 Marcel Dekker, Inc.
Let |
rc ¼ 40 atm; then |
hl ¼ 258.2 kcal=kg, hv ¼ 669 kcal=kg, Sl ¼ 0.6649, |
|||||
Sv ¼ 1.4513, vl ¼ 0.001249, vv ¼ 0.05078. |
|||||||
Hence: |
|
|
|
|
|||
x |
|
|
S Sl |
0:7983 |
0:6649 |
|
|
|
¼ |
Sv Sl |
¼ |
1:4513 |
0:6649 |
|
|
¼0:1696
v ¼ vl þ xðvv vlÞ
¼0:001249 þ 0:1696 ð0:05078 0:001249Þ
¼0:009651 m3=kg
Again, compute v at 41 atm (2.5% more than Pc). Using steps similar to those described above, v ¼ 0.0093 m3=kg.
Hence, |
ss |
|
|
|
|||||
¼ |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
mc |
|
100 |
g |
dP |
|
|
|
|
|
|
dv |
|
|
¼ |
|
||||
¼ |
|
r |
|
||||||
|
|
100 |
|
|
9:8 1 |
|
16;733 kg=m2 s |
||
|
|
|
0:00965 |
|
0:0093 |
|
|
||
|
|
|
|
|
|
||||
Compute the densities as |
|
|
|||||||
rs ¼ |
|
1 |
|
¼ 692 kg=m3 |
|
|
|||
|
|
|
|
|
|||||
0:001445 |
|
|
|
||||||
The dryness fraction at 40 atm at isenthalphic condition is
x¼ 334 258:2 ¼ 0:1845 669 258:2
vc ¼ 0:001249 þ 0:1845 ð0:05078 0:001249Þ
|
¼ 0:010387 m3=kg |
|
|
|
|
|
|
|
|
|
|
|
|
||||
rc ¼ 96:3 kg=m3 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Similarly, at Pm ¼ (100 þ 40)=2 ¼ 70 atm, |
|
|
|
||||||||||||||
vm ¼ 0:03785 m3=kg |
|
or |
|
rm ¼ 264 kg=m3 |
|
||||||||||||
|
|
ð1 v ¼ |
6 |
|
|
ð |
|
þ |
|
|
|
|
þ |
|
Þ |
||
|
104 |
2 dP |
100 40 |
|
|
692 |
|
4 |
|
|
264 |
|
96:3 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
¼ |
184 10 |
6 |
2 ln |
v2 |
|
|
|
|
|||||||
|
|
|
v1 |
|
|
|
|
|
|||||||||
|
|
¼ |
2 ln |
rs |
¼ 4:6 |
|
|
|
|
|
|
|
|
|
|||
|
|
rc |
|
|
|
|
|
|
|
|
|
|
|||||
Copyright © 2003 Marcel Dekker, Inc.