Analysis of the cycle with regeneration, an intercooling and reheating:

Fig.16. p-v and T-s diagrams of regenerative gas turbine cycle with two- stage compression and reheat

Scheme of the engine is shown in fig.17.

Fig.17. Scheme of engine with regeneration, an intercooling and reheating

1- filter; 2- compressor of low pressure; 3- compressor of high pressure; 4- main combustion chamber; 5,6- turbine; 7,11- pump; 8,10- cock; 9-additional combustion chamber; 12-intercooler; 13-regenerator

Parameters of all points are like in previous cycles but parameters at points A and B must be recalculated: ; pA=pк; ;

; pB=pн; .

Determination of changing entropy, enthalpy in processes:

Determination of work in processes and heat:

=cp(Tг-Tк); =(z-1) cр(Tг1-Tт1); qp=cp(TA-Tк);

q1= + - qp = cp(Tг-Tк) + (zexp -1)cp(Tг-Tт1) -cp(TA-Tк);

=cр(Tн- Tт); =(z-1)cp(TD-Tc); q2= + =cр(Tн - Tт)+(zcom-1)cp(TD-Tс);

wс= zcom cp (TK-TH); wexp.= zexp cp (Tг-Tт1).

Determination of net work and thermal efficiency of the cycle:

; wcycle= wexp- wс.