In the integrated flight systems accessory unit (ifsau). When

AC power is not available, a 5 minute time delay keeps the DC

power relay energized, and the right ADIRU operates on DC

power. After 5 minutes continuous operation on DC power, the

time delay circuit deenergizes the relay and DC power to the

right ADIRU is removed. This feature allows the airplane battery

to drain at a slower rate.

ADIRS - NO COOLING AND ON DC WARNING

General

The integrated flight systems accessory unit (IFSAU) contains a

circuit which causes the ground crew call horn to tell

maintenance personnel of unsafe ADIRU operation. This

occurs when the airplane is on the ground and the ADIRUs

are on dc power or when the equipment cooling system fails.

ADIRU DC Power Operation

The ADIRUs send 28v dc to the AND logic circuit in the IFSAU.

When an ADIRU senses that it is on dc power, it sends an ON

DC discrete to the IFSAU. The discrete goes through a 20

second delay to the AND gate logic. After twenty seconds of dc

operation, the AND gate supplies power to the crew call horn

relay. The relay energizes when the air/gnd relay is in the gnd

position. The energized crew call relay closes the relay switch,

and 28v dc power causes the horn to operate.

Equipment Cooling Failure

Two equipment cooling sensors monitor the cooling air flow to

the ADIRUs. A low flow relay in the sensor will close when the

cooling air flow fails. The closed relay lets 28v dc go to the

IFSAU. The 28v dc discrete goes through a 20 second delay to

the AND gate logic. After twenty seconds, the AND gate

supplies power to the crew call horn relay. The relay energizes

when the air/gnd relay is in the gnd position. The energized

crew call horn relay closes the relay switch, and 28v dc power

causes the horn to operate.

ADIRS - CONTROL AND WARNING

General

These are the units that interface to supply control and warning

data to the pilots:

* ISDU

* MSU

* IRS master caution unit.

ISDU Interface

The ISDU supplies both ADIRUs with test discretes, heading

data, and present position data. The ADIRUs supply IR data and

fault data to the ISDU.

MSU Interface

The MSU supplies mode discretes to the ADIRUs. The ADIRUs

supply align and fail discretes to the MSU. The MSU also

receives an ON DC discrete from the ADIRUs. The ON DC

discrete goes through the IRS master caution unit.

IRS Master Caution Unit Interface

The IRS master caution unit receives fail and ON DC discretes

from the ADIRUs. The IRS master caution unit supplies discrete

outputs to the MSU and to the master caution lights and

annunciators.

ADIRS - SYSTEM INPUTS

General

Each ADIRU receives inputs from these on-side components:

* AOA sensor

* Pitot ADM

* Static ADM.

The AOA sensor gives angle of attack information to the ADIRU.

The ADIRU uses angle of attack to modify pitot and static

values.

The pitot ADM gives the ADIRU total air pressure information.

This is used to calculate airspeed and mach number.

The static ADM gives the ADIRU static air pressure information.

This is used to calculate altitude and airspeed.

These components supply data to both ADIRUs:

* TAT probe

* DEU 1 and DEU 2

* Window and pitot heat module

* Inertial system display unit (ISDU)

* FMC 1 and FMC 2.

The TAT probe gives total air temperature to the ADIRUs. The

ADIRUs use TAT to modify altitude and airspeed calculations.

DEU 1 and DEU 2 give barometric correction to the ADIRUs. The

ADIRUs use barometric correction to calculate corrected

barometric altitude.

The window and pitot heat module sends a discrete signal to

the ADIRUs when anti ice heat is on. The ADIRUs modify the