Indication

The green indicator on the front panel shows the device status – on/off. There is an indicator of the device connection, there which shows whether the device is connected to a fiber optic port. Each port has three indicators in its turn.

Indicator

Color

Value

Description

Upper

Constant yellow

FDX

Operation in full-duplex mode

Blinking yellow

Col

Collision detected

Middle

Constant green

Link

Presence of physical connection

Blinking green

Activity

Data reception

Lower

Constant green

100M

Port works at 100M bit rate

Blinking green

10M

Port works at 10M bit rate

The back panel

Additional slot

The 16th port of the switch can be transformed to 100base-FX switch port. For this purpose it is necessary to install the additional unit in to an extension slot. If the unit is installed, then the 16th port on the front panel is switched of.

Power supply

Tolerable limit: from 100В to 240В, frequency: 50/60 HZ.

RS-232 console

RS-232 console is intended to manage the switch. To manage the switch by means of a personal computer it is necessary to connect one end of a cable (the cable is delivered together with the switch) to a console port of the switch, and another to СОМ1 or COM2 computer port.

FNSW-16/2400S switch setup

Connection to the PC

After the operations on connection of RS-232 console are fulfilled, it is necessary to start the remote access and Hyper Terminal control program (it goes in a standard configuration of Windows 9.x, 2000, NT) or РгоСОММ:

Hyper Terminal

After Hyper Terminal start create a new connection, having set up the following parametres:

Rate baud (rate): 19200 bps

Data byte (data bits): 8 bits

Parity Check (parity): None

Stop bit (stop bits): 1

Flow control: No

Console menu

Start the created connection, and then connect the switch. When the installation of connection is successful 6 options for console setup will be shown:

(1) Trunk/VLAN Setting (customisation of network/channel groups)

(2) Port Status (the port status)

(3) Port Setting (port customisation)

(4) Factory Setting (factory setting restoring)

(5) Redundant Link (installation of additional link)

(6) Save Setting (to save customisations)

To get to a submenu dial an option number and press «ENTER».

Setting virtual network groups (Trunk/VLAN Setting)

Having selected from the main menu the first option Trunk/VLAN Setting you will see the following menu:

Setting VLAN group (virtual network groups)

Having selected from the menu an option «2» you get to the menu of network virtual group setting:

Network groups setup.

By default: all ports belong to VLAN1 group.

To choose a network group we use the cursor.

To save settings press «SAVE».

Examples of network group set-up:

Example №1. Addition of ports to a group. Select a group, then enter a port number which you wish to include in this group. For example, VLAN2 group, port №1.

As a result you will see the following:

For further network groups setting repeat these operations.

Example №2. Common port creation.

Add the 5th port to all network groups.

When you receive the common 5th port, the first 4 ports will be divided by a server in to 4 network groups. Thus, the first four ports will become unavailable to each other directly, but they will have link through the common 5th port (such common port is named a server port).

The status of ports

The port status allows to receive information about operating modes of ports.

When you press «2» in the console menu, you will see a window in which the operating mode of ports is displayed. The given option has exclusively informational character, i.e. any changes are impossible.

AutoN – an autodetection mode

BackP – the control of a half-duplex stream (flow)

Pause – the control of a full-duplex stream (flow)

Ports set-up

When you select option «3» in the main menu of the console you are offered to enter the port number which you are going to set up:

Let's consider of ports settings on three examples:

Example №1

Let's set up port №1 for the operation in the full-duplex mode at 100Mb/s rate. For this purpose after you have chosen a number of a port to set up, select first an option «Port Mode», and then an option «100FDX»:

Example №2

Let's install a verification mode of a full-duplex stream (flow) in the 2nd port.

For this purpose the second port is selected

Then we select "Pause" operating mode of a port and activate it.

The verification mode of a full-duplex stream is an operating mode of the switch, at which in the case if the switch has no time to cope with information streams (flows) arriving at it from network devices (i.e. the switch is overloaded), it (switch) dispatches the delay frame to a network device. The device temporarily stops transmission and restores it after a small pause. It is necessary to remember, that not all devices support this function and in that case avoid the loss of packages it will not be possible to.

Example №3

Let's install a verification mode of a half-duplex stream (flow) in the 3rd port.

This mode is required in the case when the device working in the half-duplex mode, connected to the switch has not coped with processing of the arrived information and there is a collision. In this case the computers working with «a not responding» computer in one network, temporarily stop transmission and restore it anew in some pause.

Factory settings

Function assignment is to restore customizations of a manufacturer. When you select option «6» in the main menu of the console you start a recovery program of the switch configuration which has been set by a manufacturer. After restoring the system will automatically reboot (reload).

Set-up of additional link (Additional connection establishment)

This option of the console menu allows to establish additional connection. For example, the device working through the 10th port, is one of key ones in a network. Connection with it should not be interrupted under any conditions. For this purpose you create an additional line through the 9th port. In case of failure of the 10th port, the 9th port will automatically intercept its functions and the connection with the device will be carried out through it.