6.3 Mounting arrangements an cylinder dynamics

Cylinder mounting is determined by the application. There are two basic types are shown. The first one is the clamp which requires a simple fixed mounting. The second one is the pusher which requires a cylinder mount which can pivot. Figure 6-14 shows various mounting methods using these two basic types. The effects of side loads should be considered on non-centreline mountings such as the foot mount. Swivel mounting obviously requires flexible pipes.

The cylinder in Figure 6-15a is used to lift a load of mass M. Assume it is retracted, and the top portion of the cylinder is pressurized. The extending force is given by the expression:

, (6.6)

To lift the load at all, F>Mg+f where M is the mass and f the static frictional force.

The response of this simple system is shown in Figure 6-15b. At time W the rod side of the cylinder is vented and pressure is applied to the other side of the piston. The pressure on both sides of the piston changes exponentially, with falling pressure P2 changing slower than inlet pressure P1 because of the larger volume. At time X, extension force P1A is larger than P2a, but movement does not start until time Y when force, given by expression 6.6, exceeds mass and frictional force.

Figure 6-14. Methods of cylinder mountain

The load now accelerates with acceleration given by Newton's law:

, (6.7)

Where Fa = PtA - P2a - Mg - f.

It should be remembered that Fa is not constant, because both P1 and P2 will be changing. Eventually the load will reach a steady velocity, at time Z. This velocity is determined by maximum input flow rate or maximum outlet flow rate (whichever is lowest). Outlet pressure P2 is determined by back pressure from the outlet line to tank or atmosphere, and inlet pressure is given by the expression:

, (6.8)

The time from W to Y, before the cylinder starts to move, is called the 'dead time' or 'response time'. It is determined primarily by the decay of pressure on the outlet side, and can be reduced by de-pressurising the outlet side in advance or (for pneumatic systems) by the use of quick exhaust valves (described later).

The acceleration is determined primarily by the inlet pressure and the area of the inlet side of the piston (term P1A in expression 6.6).

Figure 6-15. Cylinder dynamics

The area, however, interacts with the dead time - a larger area, say, gives increased acceleration but also increases cylinder volume and hence extends the time taken to vent fluid on the outlet side.

Chapter 7 STATION LAYOUT AND FACILITIES

7.1 Station piping layout

Almost all mainline compressor stations, except the smallest, contain multiple compressor units and are designed with enough horsepower and throughput capacity to meet current firm contractual requirements levied on the system. Since most stations need to be operational 24 hours per day, 365 days a year and are unmanned, the on-site computerized flow control system (B) (Figure 7-1) sees to it that only the appropriate number of units required to meet current flow requirements ever operate at one time, thus optimizing operational efficiency and extending the life of the equipment.5

The purpose of a compressor The purpose of a compressor station is to boost the pressure in a natural gas pipeline and move the natural gas further downstream.6 Pipeline flow pressure decreases between stations because of friction between the natural gas flow and the inside wall of the natural gas pipeline and as natural gas is received and/or delivered along the route.

The natural gas stream entering the station (C) (Figure 7-1) is passed through scrubbers and filters (D) (Figure 7-1) to extract any liquids that may have condensed out of the natural gas stream as line pressure decreased and to remove any particulate matter that may have formed during contact with the materials that coat the inside of the natural gas pipeline.

Once the natural gas stream has been cleaned, it is directed through smaller piping segments assigned to individual compressor engines of varying horsepower and capacity (E) (Figure 7-1). Computers regulate the flow and number of units that are needed to handle the scheduled system flow requirements.

Figure 7-1.

Station piping and associated components common to both reciprocating and centrifugal stations can be described from the suction slide valve to the dischsrge slide valve, with reference to figure 7-2.

  1. A station suction slide valve is installed to isolate the station from the pipeline.

  2. A station loading valve is used to purge and pressurize the compressor station piping.

  3. A station scrubber is installed to clean the gas,