- •For course design
- •3 Selection of route, type of cable and transmission systems
- •3.1 Short characteristic of terminal points
- •3.2 The choice of fiber optic transmission lines route
- •3.3 Selection and justification of optic fiber type
- •3.4 Selection and justification the construction and type of optical cable
- •3.5 Selection and justification of fiber optic transmission system
- •3.6 Control questions
- •4.3 Choice and substantiation of the optical cable
- •4.2 Choice and substantiation of the type of optical fibers
- •4.2 Choice and substantiation of the Fiber optic transmission system (fots)
- •5 Calculation of optical properties of fibers and parameters of cable transfer
- •5.1 Determination of optical fiber parameters
- •5.2 Determination of losses in optical fiber
- •5.3 Calculation of running dispersion of the signal in single mode optical fiber
- •6 Calculation of regeneration length of optical fiber transmission lines, chart of energy levels
- •6.1 Calculation of the length of the regeneration section by attenuation
- •6.2 Calculate the length of the regeneration section by dispersion
- •6.3 Placement regeneration points along the route of focl
- •6.4 Constructing a chart levels of energy potential fots at the length of one area of regeneration
- •7 Protection of optical cable from the influence of external electromagnetic fields
- •Protection of optical cables from lightning strikes
- •Calculation of the dangerous effects of magnetic influences
- •Calculation of reliability of linear structures fots
- •9 Organization of works on construction and installation project lines. Budget and financial calculation of linear structures of focl
- •9.1 Organization of construction works
- •9.2 Budget and financial calculations
3.4 Selection and justification the construction and type of optical cable
Choice of construction and type optical cable determined by selected number of OF, operating conditions and the planned method of laying.
Number
of OF in the cable is determined depending on the given number of
primary digital flows and operating reserves fibers
:
where
-
quantity of OF in cable;
– quantity of ПЦП
by variant;
-
- quantity of ВОСП
ПЦП;
0,5 – coefficient, including 50 % fibers reserve for further
expansion of communication networks. This expression is true, when
the ratio
=1, then the quantity of fibers is chosen equal to 4.
The most common modular cables, the core of which includes several optical modules (with two, four or OF quantity up to 12) concluded spirally around the central word element which is used as sclomastic rod (Fig. 3.2, a) steel wire or cable in the plastic coating. Recently, however, more commonly used cables, the core of which is the one optical module with thick-walled polymer tube (Fig. 3.2, b). Type of external covers [11, 12] typically is chosen in the conditions of using OK according to table 3.8. Acceptable effort for all types of ОК, as a rule, 1000 Н/см. The minimum bending radius must be less than 20d, where d - diameter cable. Construction length of optical cables is on average 2 ... 6 km, but not less than 1 km. Within the city, usually used OK with the construction length of 1 ... 2 km.
Choosing the type of armor shell [11, 12], determine the brand of optical cable according to instructions (tab. 3.9) and select construction element data (Table 3.10). It should be noted that usually OK in marking from different manufacturers differ. One of the typical ways of marking optical cables, such as ПАТ “Завод “Південкабель” given in the Table 3.9.
Table 4.3 - Types of coatings
№
|
Laying conditions |
Installation method |
Permissible pulling stress, кН |
Armor coatings |
|
1 |
2 |
3 |
4 |
5 |
|
1. |
Directly in the sewerage |
spinning using blanks |
2,0 – 3,5
|
-without armor - corrugated steel - braid |
|
2. |
In the sewerage, in the auxiliary plastic pipes |
spinning using blanks |
2,0 – 3,5
|
the same
|
|
3. |
In the sewerage or in the soil in the tubes of the silicone coating |
spinning using blanks or using cable blowing jet |
2,0 – 3,5 |
the same
|
|
4. |
Directly into the soil of III-IV categories |
using cable stacker or into trench |
7 – 8
|
- round wire - steel tape |
|
5. |
Transitions of the navigable rivers, in swamps, rocky soil |
Depending on the conditions |
20 – 96
|
full metal jacket with armor of round wires |
|
6. |
On airlines |
Hanging on poles |
15 – 25 or more depending on the length of section and wind loading |
– fiberglass – synthetic yarn with high elasticity
|
|
Таблиця 3.9 – Marcoformation of optical cables
1
|
||||||||||||||||||||||||||
1 |
2 |
3 |
4 |
|||||||||||||||||||||||
1 |
Тип кабелю / Type of cable |
O |
волоконно-оптичний / fiber optic |
|||||||||||||||||||||||
2 |
Наявність захисного шару Protective layer
|
а |
виконання з алюмополімерним захисним шаром with alumopolymer protective layer |
|||||||||||||||||||||||
Без позначення Without designation |
без алюмополімерного захисного шару / without alumopolymer protective layer |
|||||||||||||||||||||||||
1 |
2 |
3 |
4 |
|||
3 |
Тип броні або армуючих елементів
Type of armouring or the armouring elements
|
Ар |
шар арамідних ниток / layer of aramid threads |
|||
Би |
броня з двох сталевих оцинкованих стрічок, накладених спірально / armour of two spirally laid steel galvanized tapes |
|||||
Бг
|
броня із сталевої гофрованої стрічки, накладеної поздовжньо / armour of longitudinally laid steel zetabon tape |
|||||
|
|
К
|
броня з одного повива круглих сталевих оцинкованих дротів / armour of one layer of circular steel galvanized wires |
|||
2К
|
броня з двох повивів круглих сталевих оцинкованих дротів / armour of two layers of circular steel galvanized wires |
|||||
Сп |
броня з повива склопластикових стержнів / armour of fiberplastic rods |
|||||
Без позначення Without designation |
без броні і армуючих елементів / without armour and the armouring elements
|
|||||
4 |
Тип захисного шлангу
Outer sheath type
|
П |
поліетиленовий шланг / polyethylene sheath |
|||
Пн
|
Захисний шланг з полімерної композиції, що не розповсюджує горіння / sheath of flame retardant polymer compound |
|||||
Пп
|
проміжна поліетиленова оболонка між повивами бронепокровів типу 2К і зовнішній захисний шланг / inner polyethylene sheath between the layers of the armouring of 2K type and the outer polyethylene sheath |
|||||
5 |
Тип центрального силового елементу
Central strength element type
|
З
|
сталевий трос або сталевий дріт з поліетиленовим покриттям / steel rope or steel wire with polyethylene coating |
|||
Без позначення Without designation |
діелектричний ЦСЕ (склопластиковий пруток і тому подібне) / dielectric central strength element (fiberplastic rod and etc.) |
|||||
6 |
Тип температурних виконань
Temperature type making |
ХЛ
|
від мінус 60°С до плюс 60°С / From minus 60°С up to 60°С |
|||
Без позначення Without designation |
від мінус 40°С до плюс 60°С / from minus 40°С up to 60°С |
|||||
7 |
Кількість ОВ в кабелі / Quantity of optical fibers in the cable |
|||||
8 |
Тип ОВ
Optical fiber type
|
E
|
одномодове, відповідно до рекомендацій ITU-T G.652B / single-mode as per the recommendations of ITU-T G.652B |
|||
A
|
одномодове з розширеною робочою смугою довжин хвиль, відповідно до рекомендацій ITU-T G.652D / enhanced single mode optical fibre (ESMF) as per the recommendations of ITU-T G.652D |
|||||
C
|
одномодове з ненульовою зміщеною дисперсією, відповідно до рекомендацій ITU-T G.655 / non zero single mode shifted as per the recommendations of ITU-T G.655 |
|||||
M
|
багатомодове зі співвідношенням діаметрів осердя та оболонки - 50/125 мкм, відповідно до рекомендацій ITU-T G.651 / multimode with core and sheath ratio of 50/125 mkm as per the recommendations of ITU-T G.651 |
|||||
B
|
багатомодове зі співвідношенням діаметрів осердя і оболонки - 62,5/125 мкм, відповідно до рекомендацій МЕК 60793-2 / multimode with with core and sheath ratio of 62,5/125 mkm as per the recommendations of IEC 60793-2 |
|||||
9 |
Кількість елементів у повиві осердя / Number of elements in the core |
|||||
10 |
Розподіл оптичних волокон за модулями / Optical fibers distribution in tubes |
|||||
11 |
Кількість ізольованих мідних жил в кабелі (при їх відсутності - без позначення) Quantity of copper insulated wires in cable (without designation on their absence) |
|||||
12 |
Допустиме розтягуюче зусилля кабелю, кН / Permissible pulling stress, kN |
|||||
Таблиця 3.10 – Specification of optical cable elements
№ |
Name of element |
Geometrical dimention of element (diameter, thickness etc.) |
Material and construction features of element |
|
|
|
|