- •Preface
- •►Acknowledgements
- •►Med Man Simulations Inc, a nonprofit corporation
- •►Reviews of and writing about and using gas man®
- •Table of Contents
- •Introduction
- •Concepts Covered in the Gas Man Tutorial, by Chapter
- •The Gas Man Approach
- •Uses for Gas Man
- •►To teach
- •►To explore clinical practice
- •►To plan
- •►To reduce costs
- •►To interpret monitors
- •Other Users of Gas Man
- •Summary
- •Introduction
- •Your Software License
- •The Single User License
- •The Site License
- •The Site License authorizes users to copy the Gas Man software and the pdf version of the tutorial (this document) and to install them on computers within their
- •Copying & Distributing the Manual & Software
- •Installing Gas Man on Windows™ or Macintosh Computers Hardware Requirements
- •Installing the Software under a Single User or Site License
- •►If you have an installation problem
- •The Gas Man Control, Picture, and Graph
- •Setting Parameters
- •The Gas Man Menus & Toolbar
- •Main Menu file menu
- •Edit menu
- •Anesthesia menu
- •View menu
- •Special menu
- •Working With Multiple Views
- •Running a Gas Man Simulation Exercise 2-1: Running a Simple Simulation
- •Exercise 2-2: Replaying and Revising a Simulation
- •Using Bookmarks
- •Summary
- •Exercise 3-1: Wash-in of a Single Compartment
- •Observation
- •Discussion
- •Observation
- •Exercise 3-3: The Shape of the Exponential Curve
- •Summary
- •Exercise 4-1: The Step Response of a Perfectly Mixed Circuit
- •Exercise 4-2: The Alveolar Step Response
- •Discussion
- •Observation
- •Discussion
- •Observation
- •Summary
- •Exercise 5-1: The Open Circuit Alveolar Tension Curve
- •Discussion
- •Exercise 5-2: The Initial Rise in the Alveolar Tension Curve
- •Observation
- •Exercise 5-4: Uptake Produces a Knee and Plateau in Alveolar Tension
- •Observation
- •Exercise 5-5: Increasing Alveolar Ventilation Raises the Knee and Plateau Increasing alveolar ventilation raises the knee and plateau of the alveolar tension curve
- •Observation
- •Exercise 5-6: Increasing Cardiac Output Lowers the Knee and Plateau
- •Increasing cardiac output lowers the knee and plateau of the alveolar tension curve.
- •Observation
- •Exercise 5-7a: Ratio of va to Effective co Determines Plateau Height
- •Observation
- •Exercise 5-7b: Plateau Increases with va
- •Observation
- •Exercise 5-7c: Plateau Increases inversely with co
- •Observation
- •Discussion
- •Exercise 5-8: Anesthetic in Venous Blood causes Gently-Rising Tail
- •Figure 5-8b displays the Picture and Graph after the transition from venous return disabled to normal venous return.
- •Figure 5-8c shows superimposed graphs with and without anesthetic in venous return.
- •Discussion
- •Summary
- •Exercise 6-1: Alveolar Tension Curves Have the Same General Shape
- •Observation
- •Figure 6-1e shows the Picture and Graph after administering desflurane at constant inspired tension of 18% for 15 minutes.
- •Exercise 6-2: High λB/g Drugs Have Low Plateau and a/I or e/I
- •Observation
- •Exercise 6-3: Determining the Initial Overpressure Value
- •Exercise 6-4: Choosing the Solubility-adjusted Overpressure
- •Observation
- •Summary
- •Exercise 7-1: Maintaining 1 mac Using Overpressure
- •Observation
- •Exercise 7-2: Optimum Anesthesia Uses Overpressure
- •Discussion
- •Exercise 7-3: Optimum Clinical Anesthesia Using Overpressure
- •Summary
- •Exercise 8-1: The Concentration Effect
- •Discussion
- •Exercise 8-2: Concentration Effect Varies with Inspired Concentration
- •% Nitrous oxide is inspired.
- •Exercise 8-3: At 100%, co Has No Effect on alv
- •Exercise 8-4: Concentration Effect depends on Uptake Effect
- •Summary
- •Exercise 9-1: Reducing Fresh Gas Flow
- •Observation
- •Discussion
- •Exercise 9-2: Circuit Flush Is Faster
- •Observation
- •Discussion
- •Exercise 9-3: In a Perfect World…
- •In an Ideal circuit, fresh gas fills the circuit first and then mixes with exhaled gas.
- •Summary
- •Exercise 10-1: Simulating Liquid Injection
- •Observation
- •Exercise 10-2: Liquid Injection Can Produce Optimum Anesthesia
- •Discussion
- •Exercise 10-3: Classic Closed-circuit Approach
- •Summary
- •Exercise 11-1: at Low Concentration, the Second Gas Effect is Slight
- •Exercise 11-2: at High Concentration, the Second Gas Effect is Dramatic
- •Observation
- •Exercise 11-3: Concentration Effect Using 70% Nitrous Oxide
- •Observation
- •Summary
- •Exercise 12-1: Wake Up Is the Inverse of Induction
- •Discussion
- •Exercise 12-2: Lower Solubility Means Lowers Alveolar Wake-up Tension
- •Observation
- •Figure 12-2b shows the Overlay View of vrg/mac from the simulations run in Exercise 12-2, simulating patient wake up after a 10-hour anesthetic with isoflurane, sevoflurane and desflurane. Discussion
- •Time to Reach 0.33 mac (minutes)
- •Summary
- •Exercise 13-1: Kinetics is Faster in Smaller Patients Kinetics is faster with patients of lower size
- •Observation
- •Exercise 13-2: Kinetics is Faster in Smaller Animals
- •Observation
- •Summary
- •Exercise 14-1: Determining Cost to Achieve 1 mac
- •Observation
- •Discussion
- •Exercise 14-2: Cost to Achieve 1 mac is Lower with Lower fgf
- •Observation
- •Discussion
- •Figure 14-2c shows the Overlay View of the alv/mac curves in Exercises 14-1 (high flow) and 14-2 (low flow).
- •Exercise 14-3: Low Flow Techniques with New Agents
- •Observation
- •Observation
- •Figure 14-4 shows the Overlay View comparing the cost curves of administering isoflurane and desflurane with regular and low-flow techniques.
- •Discussion
- •Summary
- •Discussion
- •Summary
- •Exercise 17-1: Circuit Prime
- •Observation
- •Exercise 17-2: vci Brings Expired to 2 mac Immediately, vrg to 1.5 mac Easily Vital Capacity Induction immediately brings expired tension to 2 mac, then vrg to 1.5 mac with ease
- •Exercise 17-3: Turning Vaporizer Off Delivers Negative Bolus Turn the vaporizer off to achieve a negative bolus
- •Observation
- •Exercise 17-4: Achieving 2 mac in the brain after Vital Capacity Induction vci to prepare the patient for intubation without the need for other drugs
- •Observation
- •Summary
- •Exercise 18-1: Maintenance of 1 mac anesthesia until the end of surgery Maintain anesthetic depth through surgery and rapid wake-up
- •Observation
- •Summary
- •Exercise 19-1: Turning fgf and del Down Too Early
- •Observation
- •Exercise 19-2: Maintaining fgf and del after alv Reaches 1 mac
- •Observation
- •Summary
- •Evolution of the Understanding, Modeling & Simulation of Anesthesia
- •The Gas Man Approach
- •Model Parameters
- •Tissue/Gas partition coefficients
- •Tissue/Gas partition coefficients (calculated)
- •Further Considerations on the Use of Gas Man®
- •Organ Volumes
- •Organ Blood Flows
- •Breathing Circuit
- •Shunts and Dead Space
- •Inter-tissue Diffusion
- •Summary
- •Gas Man System Defaults
- •Toolbar Additions
- •Go/Stop Toggle Button.
- •Show Cost / Show Volume Toggle Button
- •Vaporization Effect mathematics added through Special Menu
- •Advanced Features of Gas Man
- •Advanced Inputs and Parameters Custom and Customized Anesthetics
- •Program, View, Simulation, Anesthetic, Color and Patient Defaults
- •View Defaults
- •Bookmarks
- •Advanced Program Operations Saving, Opening, and Sharing Simulations
- •Table e-1: Program Parameters in .Gas files
- •Table e-4: Simulation parameters in .Gas files
- •View Settings
- •Table e-5: View settings in .Gas files Replaying Simulations
- •Tabs, Windows and Panels (The Model, View, Controller Pattern)
- •Multiple Agent Simulations
- •Circuit flush
- •Interface Enhancements Scrolling
- •Scaling
- •Using the Overlay Feature
- •Modeling
- •Vaporization, injection and uptake
- •The Ideal Circuit
- •Advanced Outputs
- •Printing and Previewing
- •Exporting to pdf, html and xml
- •Capture and Copy
Preface
There are many uses for computer technology within the practice of anesthesia. Usually, computers are used to automate practices which are already well-established. Using the computer to help teach difficult concepts is another matter, however, that goes far beyond the automation of procedure. Computer-aided learning is difficult to develop, but very rewarding in its effectiveness. This program, Gas Man®, exploits this medium and helps learners understand anesthesia uptake and distribution.
The fundamental principles underlying anesthetic pharmacokinetics are simple. The two important rules are conservation of mass and physiologic maintenance of lung volume. Unfortunately, the dynamic implications of these principles are not easy to comprehend. Indeed, it is the need for explanation and demonstration of the dynamic changes in anesthetic tension equilibration which led me to design and implement this educational tool.
The Gas Man program is a powerful marriage of computer simulation and image production with the written word. In place of the instructor in a simulation laboratory, we have the instructor's voice (in print) and a laboratory, both inside a personal computer. By using the set of exercises in this Manual, and by learning how to use Gas Man as a tool for further exploration, users can study the simplicities and subtleties of the dynamic properties of anesthesia uptake and distribution regardless of where they are or what other resources are available to them.
I first began investigating the use of computers to help teach the concepts of anesthesia uptake and distribution in 1980, when I received a grant from the Apple Educational Foundation to explore the use of Apple II computers. In 1982 the first version of Gas Man for the Apple II was shown at the American Society of Anesthesiologists meeting and then the New York Society of Anesthesiologists Post Graduate Assembly (NYSA-PGA) where it won a Special Award. The program and a set of exercises similar to this Manual was published and distributed by Addison- Wesley in 1984. After many colleagues clamored for an updated version of the program suitable for microcomputers, we demonstrated in 1989 a version of Gas Man® for the Macintosh. In 1994 we released Gas Man® for Windows®, and Version 2.1, with many new features, was released in conjunction with this manual in October 1995. As computer operating systems evolved, so did Gas Man, each time adopting the latest Graphical User Interface (GUI) features.
Gas Man's new features significantly broaden the base of users and uses. The ability to compare and contrast anesthetic techniques and agent choices should attract a solid following by hospital administrators, pharmacists, and anyone concerned with the cost of health care.
The ability of the Gas Man Overlay to normalize tensions to agent MAC and then explore the effects of blood/gas solubility provides drug and equipment manufacturers with insights not previously available. Vaporizers for new agents sevoflurane and desflurane have maximum dial settings that account for both MAC and solubility, allowing the same relative alveolar overpressure found with halothane and desflurane vaporizers. Gas Man insights played a role in designing new vaporizers. Meanwhile, clinicians can use the same displays to compare and contrast administrations with different drugs and different techniques. Gas Man's wide ideal- body weight range - from 50 g to 1500 Kg - animals of interest to veterinarians can now be simulated with ease.
i | P a ge
Gas Man has been reviewed favorably in numerous publications1, 2, 3, 4, 5, 10. Several studies have demonstrated the effectiveness of Gas Man as an educational tool in centers other than where it was written6, 7 and when compared to lecture presentation8. Ongoing study of its efficacy as a simulation program has endorsed its accuracy9. More recently, others have demonstrated that Gas Man accurately predicts expired anesthetic concentrations during induction and upon emergence after anesthetics of short and long duration11 . One recent study used Gas Man to explore context-sensitive decrement times across a wide spectrum of anesthetics, anesthetization periods, and decrement criteria12. I am committed to the wide-ranging audience of Gas Man users to continue to refine and enhance the program and its applications.