- •Глава 1 обзор газового манда и его использования 1
- •Глава 2 начало работы с gas man® 8
- •Глава 3 одна коммутационная модель 24
- •Глава 4 двух последовательных отделений 35
- •Глава 5 алвеоларная напряженная кривка 43
- •Preface
- •►Acknowledgements
- •►Med Man Simulations Inc, a nonprofit corporation
- •►Reviews of and writing about and using gas man®
- •Table of Contents
- •Introduction
- •Concepts Covered in the Gas Man Tutorial, by Chapter
- •The Gas Man Approach
- •Uses for Gas Man
- •►To teach
- •►To explore clinical practice
- •►To plan
- •►To reduce costs
- •►To interpret monitors
- •Other Users of Gas Man
- •Summary
- •Introduction
- •Your Software License
- •The Single User License
- •The Site License
- •The Site License authorizes users to copy the Gas Man software and the pdf version of the tutorial (this document) and to install them on computers within their
- •Copying & Distributing the Manual & Software
- •Installing Gas Man on Windows™ or Macintosh Computers Hardware Requirements
- •Installing the Software under a Single User or Site License
- •►If you have an installation problem
- •The Gas Man Control, Picture, and Graph
- •Setting Parameters
- •The Gas Man Menus & Toolbar
- •Main Menu file menu
- •Edit menu
- •Anesthesia menu
- •View menu
- •Special menu
- •Working With Multiple Views
- •Running a Gas Man Simulation Exercise 2-1: Running a Simple Simulation
- •Exercise 2-2: Replaying and Revising a Simulation
- •Using Bookmarks
- •Summary
- •Exercise 3-1: Wash-in of a Single Compartment
- •Observation
- •Discussion
- •Observation
- •Exercise 3-3: The Shape of the Exponential Curve
- •Summary
- •Exercise 4-1: The Step Response of a Perfectly Mixed Circuit
- •Exercise 4-2: The Alveolar Step Response
- •Discussion
- •Observation
- •Discussion
- •Observation
- •Summary
- •Exercise 5-1: The Open Circuit Alveolar Tension Curve
- •Discussion
- •Exercise 5-2: The Initial Rise in the Alveolar Tension Curve
- •Observation
- •Exercise 5-4: Uptake Produces a Knee and Plateau in Alveolar Tension
- •Observation
- •Exercise 5-5: Increasing Alveolar Ventilation Raises the Knee and Plateau Increasing alveolar ventilation raises the knee and plateau of the alveolar tension curve
- •Observation
- •Exercise 5-6: Increasing Cardiac Output Lowers the Knee and Plateau
- •Increasing cardiac output lowers the knee and plateau of the alveolar tension curve.
- •Observation
- •Exercise 5-7a: Ratio of va to Effective co Determines Plateau Height
- •Observation
- •Exercise 5-7b: Plateau Increases with va
- •Observation
- •Exercise 5-7c: Plateau Increases inversely with co
- •Observation
- •Discussion
- •Exercise 5-8: Anesthetic in Venous Blood causes Gently-Rising Tail
- •Figure 5-8b displays the Picture and Graph after the transition from venous return disabled to normal venous return.
- •Figure 5-8c shows superimposed graphs with and without anesthetic in venous return.
- •Discussion
- •Summary
- •Exercise 6-1: Alveolar Tension Curves Have the Same General Shape
- •Observation
- •Figure 6-1e shows the Picture and Graph after administering desflurane at constant inspired tension of 18% for 15 minutes.
- •Exercise 6-2: High λB/g Drugs Have Low Plateau and a/I or e/I
- •Observation
- •Exercise 6-3: Determining the Initial Overpressure Value
- •Exercise 6-4: Choosing the Solubility-adjusted Overpressure
- •Observation
- •Summary
- •Exercise 7-1: Maintaining 1 mac Using Overpressure
- •Observation
- •Exercise 7-2: Optimum Anesthesia Uses Overpressure
- •Discussion
- •Exercise 7-3: Optimum Clinical Anesthesia Using Overpressure
- •Summary
- •Exercise 8-1: The Concentration Effect
- •Discussion
- •Exercise 8-2: Concentration Effect Varies with Inspired Concentration
- •% Nitrous oxide is inspired.
- •Exercise 8-3: At 100%, co Has No Effect on alv
- •Exercise 8-4: Concentration Effect depends on Uptake Effect
- •Summary
- •Exercise 9-1: Reducing Fresh Gas Flow
- •Observation
- •Discussion
- •Exercise 9-2: Circuit Flush Is Faster
- •Observation
- •Discussion
- •Exercise 9-3: In a Perfect World…
- •In an Ideal circuit, fresh gas fills the circuit first and then mixes with exhaled gas.
- •Summary
- •Exercise 10-1: Simulating Liquid Injection
- •Observation
- •Exercise 10-2: Liquid Injection Can Produce Optimum Anesthesia
- •Discussion
- •Exercise 10-3: Classic Closed-circuit Approach
- •Summary
- •Exercise 11-1: at Low Concentration, the Second Gas Effect is Slight
- •Exercise 11-2: at High Concentration, the Second Gas Effect is Dramatic
- •Observation
- •Exercise 11-3: Concentration Effect Using 70% Nitrous Oxide
- •Observation
- •Summary
- •Exercise 12-1: Wake Up Is the Inverse of Induction
- •Discussion
- •Exercise 12-2: Lower Solubility Means Lowers Alveolar Wake-up Tension
- •Observation
- •Figure 12-2b shows the Overlay View of vrg/mac from the simulations run in Exercise 12-2, simulating patient wake up after a 10-hour anesthetic with isoflurane, sevoflurane and desflurane. Discussion
- •Time to Reach 0.33 mac (minutes)
- •Summary
- •Exercise 13-1: Kinetics is Faster in Smaller Patients Kinetics is faster with patients of lower size
- •Observation
- •Exercise 13-2: Kinetics is Faster in Smaller Animals
- •Observation
- •Summary
- •Exercise 14-1: Determining Cost to Achieve 1 mac
- •Observation
- •Discussion
- •Exercise 14-2: Cost to Achieve 1 mac is Lower with Lower fgf
- •Observation
- •Discussion
- •Figure 14-2c shows the Overlay View of the alv/mac curves in Exercises 14-1 (high flow) and 14-2 (low flow).
- •Exercise 14-3: Low Flow Techniques with New Agents
- •Observation
- •Observation
- •Figure 14-4 shows the Overlay View comparing the cost curves of administering isoflurane and desflurane with regular and low-flow techniques.
- •Discussion
- •Summary
- •Discussion
- •Summary
- •Exercise 17-1: Circuit Prime
- •Observation
- •Exercise 17-2: vci Brings Expired to 2 mac Immediately, vrg to 1.5 mac Easily Vital Capacity Induction immediately brings expired tension to 2 mac, then vrg to 1.5 mac with ease
- •Exercise 17-3: Turning Vaporizer Off Delivers Negative Bolus Turn the vaporizer off to achieve a negative bolus
- •Observation
- •Exercise 17-4: Achieving 2 mac in the brain after Vital Capacity Induction vci to prepare the patient for intubation without the need for other drugs
- •Observation
- •Summary
- •Exercise 18-1: Maintenance of 1 mac anesthesia until the end of surgery Maintain anesthetic depth through surgery and rapid wake-up
- •Observation
- •Summary
- •Exercise 19-1: Turning fgf and del Down Too Early
- •Observation
- •Exercise 19-2: Maintaining fgf and del after alv Reaches 1 mac
- •Observation
- •Summary
- •Evolution of the Understanding, Modeling & Simulation of Anesthesia
- •The Gas Man Approach
- •Model Parameters
- •Tissue/Gas partition coefficients
- •Tissue/Gas partition coefficients (calculated)
- •Further Considerations on the Use of Gas Man®
- •Organ Volumes
- •Organ Blood Flows
- •Breathing Circuit
- •Shunts and Dead Space
- •Inter-tissue Diffusion
- •Summary
- •Gas Man System Defaults
- •Toolbar Additions
- •Go/Stop Toggle Button.
- •Show Cost / Show Volume Toggle Button
- •Vaporization Effect mathematics added through Special Menu
- •Advanced Features of Gas Man
- •Advanced Inputs and Parameters Custom and Customized Anesthetics
- •Program, View, Simulation, Anesthetic, Color and Patient Defaults
- •View Defaults
- •Bookmarks
- •Advanced Program Operations Saving, Opening, and Sharing Simulations
- •Table e-1: Program Parameters in .Gas files
- •Table e-4: Simulation parameters in .Gas files
- •View Settings
- •Table e-5: View settings in .Gas files Replaying Simulations
- •Tabs, Windows and Panels (The Model, View, Controller Pattern)
- •Multiple Agent Simulations
- •Circuit flush
- •Interface Enhancements Scrolling
- •Scaling
- •Using the Overlay Feature
- •Modeling
- •Vaporization, injection and uptake
- •The Ideal Circuit
- •Advanced Outputs
- •Printing and Previewing
- •Exporting to pdf, html and xml
- •Capture and Copy
Summary
The Gas Man program is a unique tool for teaching and simulating anesthesia uptake and distribution. It can be used with the exercises in this manual for a clear, detailed presentation of concepts, accompanied by direct, interactive simulations to demonstrate these concepts and reinforce learning. It can also be used as a general tool for the practicing anesthesiologist, nurse anesthetist, technician or product developer to simulate the interactions of physiological, pharmacological and physical components.
Introduction
In this chapter, you will find:
your software license agreement
how to install Gas Man® on Windows™ and Macintosh™ computers
an introduction to the Gas Man Picture and Graph
an explanation of Gas Man's menu bar and toolbar on Windows and Macintosh computers
your first exercise in Gas Man, showing you how to run a simple simulation When you finish this chapter, you will be ready to run Gas Man simulations on your own.
Note: This chapter assumes that you are already familiar with the Windows or Macintosh computer on which you plan to run Gas Man. If you are not comfortable with how your computer works, please complete an introductory tutorial on your computer's operating system before starting to use Gas Man.
Your Software License
Gas Man® is licensed to you in one of two ways: either under a Site License owned by your Anesthesia Department or University or under a Single User License. The Site License and Single User License are fully described in the License Agreement that accompanies the software and is printed in the back of the complete Gas Man® Workbook and Laboratory Guide.
The Single User License
The Single User License is intended for a single user on one computer such as a desktop or portable. Under the Single User License, you may not install the Gas Man software on more than one computer. If you wish to put Gas Man on a different machine of yours other than the one where you first installed it, you must remove it from the original machine. In addition, under the Single User License, you may not make copies of the software or this manual to distribute to others.
The Site License
The Site License is designed for single department of a university, hospital, or manufacturer of drugs, monitors, or gas machines. The exact organization is defined in the Site License Agreement.
The Site License authorizes users to copy the Gas Man software and the pdf version of the tutorial (this document) and to install them on computers within their
organization. Salespersons representing drug or device manufacturers are required to own individual licenses, and are not authorized to make and distribute copies of the software or the Manual.
In earlier years, the Site License included a specified number of copies of the Workbook and Laboratory Guide. Now that the workbook is an electronic document this no longer applies.
Copying & Distributing the Manual & Software
The full Workbook and Laboratory Guide and this excerpt are protected under applicable Copyright law. They may not be copied for redistribution under either the Single User License or the Site License. Under both the Single User License and the Site License, a user may download the latest revision of any Gas Man release from the Gas Man web site (http://gasmanweb.com). The key that was issued with the original program will continue to work for all revisions having the same major release number.
