If the level of liquids rises too high in the separator, the operator should check the:

A - Temperature controls and the control valve block valves B - Backpressure controller and temperature controls C - Dump valve controller and temperature controls D - Dump valve controller and the control valve block valves Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 3:

One method of solving the problem of foaming in separators is:

A - Allowing the foam to discharge with the overhead gas B - Cleaning the interior surfaces of the separator. C - Coating the internal surfaces of the separator D - Opening the separator dump valve fully Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 4:

Plugged or blocked lines to a level control column will cause:

A - Liquid carry over with the gas B - Gas breakthrough with the condensate C - Foaming in the separator D - False liquid level indications E - Liquid carry over with the gas and false liquid level indications Correctness Rule: Single Correct Answer Required Answer(s) Given: E Correct Answer(s): E Marked as: Correct _______________________________________________

Question 5:

The temperature in the separator is different than the fluid temperature entering the separator.

A - True B - False Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 6:

In general, which of the following factors should be considered when choosing the size and type of separator:

A - Gas flow rate, in cubic metres per day B - Specific gravities of oil, water, and gas C - Temperatures and pressures at which the separator will operate D - All of the above Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 7:

Liquid surging or slugging into a separator can be prevented by:

A - The application of inhibitors B - Proper selection and design of the separator C - The correct operation of the gathering system D - Both proper selection and design of the separator and the correct operation of the gathering system Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 8:

Controls that are most prevalent on separators are:

A - High liquid level and pressure B - High temperature and low liquid flow C - Low liquid flow and high temperature and gas flow D - High liquid flow Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 9:

One method of remedying the problem of foaming in separators is:

A - Closing the liquid inlet B - Discharge the foam with the overhead gas C - Monitoring injected fluids D - Opening the dump valve Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 10:

Liquid surging is the rapid:

A - Rise of temperature of liquids prior to separation B - Exit of liquid slugs into the pipeline from the lower portions of the separator C - Exit of liquids with the overhead gas D - Entry of liquid slugs into the separator from the lower portions of the pipeline Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct Question 1: