If the fractionator bottom temperature is too hot:

A - The tower temperature must be adjusted by changing the reflux flow B - Some of the bottom product will be driven overhead C - The reflux accumulator must be shut down D - Some of the overhead product will condense out in the bottom product Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 7:

With the flooded condenser, the tower pressure is controlled by the rate the product flows to the reflux accumulator from storage.

A - True B - False Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 8:

If a fractionator is used to condense lpg and heavier products, the type of condenser used is a:

A - Water-cooled condenser B - Total condenser C - Reflux accumulator D - Fin fan cooler Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 9:

A fractionator feed heater is a:

A - Heat exchanger B - Accumulator C - Reboiler D - Condenser Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 10:

The component labeled "A" on the illustration of the horizontal fired heater shown is called the:

A - Breeching B - Stack C - Burner D - Firebox Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Question 1:

The component labeled "F" on the illustration of the horizontal fired heater shown is called the:

A - Convection tubes B - Breeching C - Firebox D - Burner Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 2:

The component labeled "A" on the illustration of the horizontal fired heater shown is called the:

A - Stack B - Breeching C - Firebox D - Burner Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 3:

The component labeled "B" on the illustration of the horizontal fired heater shown is called the:

A - Refractory lining B - Breeching C - Stack D - Radiant tubes Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 4:

Which type of heating equipment used in a fractionation system receives all the flow from the bottom tray?

A - Fractionator feed heater B - Assisted thermal siphon reboiler C - Thermal siphon reboiler D - Fired heater reboiler Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 5: