If a fractionator is used to condense lpg and heavier products, the type of condenser used is a:

A - Total condenser B - Reflux accumulator C - Water-cooled condenser D - Fin fan cooler Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 2:

Which type of heating equipment used in a fractionation system uses only convection to produce circulation?

A - Fractionator feed heater B - Thermal siphon reboiler C - Assisted thermal siphon reboiler D - Fired heater reboiler Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 3:

The reflux accumulator, or reflux drum, is part of the condensing equipment. The accumulator pressure corresponds to the bubble point pressure of the liquid at its temperature in the vessel.

A - True B - False Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 4:

Heat exchangers experience temperature differentials on start-up that can produce high thermal stresses. To overcome this problem a type of exchanger is used called a:

A - Double pipe exchanger B - Plate heat exchanger C - Floating head exchanger D - Fixed tube sheet exchanger Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 5:

A total condenser is:

A - A heat exchanger containing finned tubes to increase the surface of the exchanger B - Used to condense the entire vapour product coming from the top of the fractionator C - A partial condenser through which the flow of cooling water is regulated D - The part of the condensing equipment that receives the condensed overhead product before it is pumped back into the tower or to storage Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 6:

If you were operating a tower where the bottom temperature is controlled by constant heat input to the reboiler, how would you control the tower temperature?

A - By reducing the power consumption of the reflux pumps B - By controlling the pressure differential between the top and bottom C - By adjusting the pressure difference between the rectifying and stripping sections D - By changing the reflux flow Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 7:

The component labeled "F" on the illustration of the horizontal fired heater shown is called the:

A - Burner B - Firebox C - Breeching D - Convection tubes Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 8:

A fired heater reboiler:

A - Uses only convection to provide circulation B - Provides the heat to partially vapourize the fractionator bottom product C - Requires a positive flow to prevent overheating of the tubes in the reboiler D - Receives all the flow from the bottom tray Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 9:

The component used with a fractionation tower that provides reflux to the tower is called the:

A - Reboiler B - Overhead condenser C - Reflux pump D - Bottom heat exchanger Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 10:

A partial condenser is an overhead product water-cooled condenser:

A - Through which the flow of cooling water is regulated B - Receives the condensed overhead product before it is pumped back into the tower or to storage C - Containing finned tubes to increase the surface of the exchanger D - Is used to condense the entire vapour product flow coming from the top of the fractionator Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A

Question 1:

The component labeled "F" on the illustration of the horizontal fired heater shown is called the:

A - Convection tubes B - Burner C - Firebox D - Breeching Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 2:

The component used with a fractionation tower that provides reflux to the tower is called the:

A - Bottom heat exchanger B - Reflux pump C - Overhead condenser D - Reboiler Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 3:

Which type of heating equipment used in a fractionation system uses only convection to produce circulation?

A - Fired heater reboiler B - Assisted thermal siphon reboiler C - Thermal siphon reboiler D - Fractionator feed heater Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 4:

To prevent overheating of the tubes in the heater, the flow through a fired heater reboiler must be:

A - Counter-current B - Negative C - Positive D - Vertical Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 5: