Protective glass

Schüco safety glass Protect (optionally available with VdS approved alarm system) offers maximum efficiency against burglary and vandalism thanks to an optimum combination of glass thickness and pane construction. Light penetration, visibility and transparency are retained so that design and functionality requirements are also fulfilled.

More components for added security for windows and doors

  • Magnetic switches for electronic monitoring of opening and closing, VdS

class C

  • Security bars

  • Multi-point claw bolt lock

  • Claw bolt lock with three-point locking

  • Fastenings in the frame to prevent levering out

  • Emergency exit switches

  • Panic locks

  • Electric locking with electric access control system

  • Security door infill panels

  • Schüco security profile cylinders

Unit 12

1. Read and translate the text lighting and ventilation requirements

In terms of the National Building Regulations, all habitable rooms, including bathrooms, showers and toilets (and interestingly enough garages!) must have some form of lighting and ventilation that will enable people to use these rooms safely. The most important aspect is that it shouldn’t be detrimental to the health of those using the room for the purpose for which it was designed.

If bathrooms are cold and perpetually damp, mould will start to form, and this can make people extremely ill. It will also make the room uncomfortable.

Changes to Part O of the NBR (when the legislation was updated a few years ago) include a welcome move from WC (short for water closet – and a very Victorian term) to “toilet”.

There are also quite substantial changes to this section of the regulations. While the lighting and ventilation regulations are generally “deemed to satisfy” if they quite simply meet the requirements of SANA 10400-O, the NBR states that if there is not sufficient natural light from windows in habitable rooms, as well as corridors, lobbies and on staircases, artificial lighting MUST be provided.

Reasons for inadequate lighting might be due to:

  • the size or shape of the room or space, or

  • the use of thick, patterned or opaque glass for windows, which prevents natural light from illuminating the room.

Similarly, if there is insufficient ventilation, artificial ventilation MUST be installed.

Reasons for inadequate ventilation include:

  • high temperatures which could be dangerous to either the safety or health of those using the room,

  • dust, gases, vapour, “volatile matter” or “hazardous biological agents” that might be dangerous to health or safety, or

  • the purpose for which the room is used may make natural ventilation unsuitable or inadequate.

Compliance Required for Lighting

While the Act states that, “Any habitable room in any dwelling house or dwelling unit, or any bedroom in any building used for residential or institutional occupancy” MUST have at least one opening for natural light – even if there is artificial lighting.

Compliance Required for Ventilation

It doesn’t matter where in South Africa you live, any artificial ventilation system MUST be authorized by your local authority (council or municipality, or City) according to their own specific policies and opinions.

This applies to everything other than regular air conditioners and other appliances installed essentially for comfort.

Further, the “rational design” of any artificial ventilation system must be performed or supervised by an “approved competent person”.