Intel® Light-Guided Diagnostics

Intel® Server Boards S5000PSL and S5000XSL TPS

7.3System ID LED and System Status LED

The server board provides LEDs for both system ID and system status. These LEDs are located in the rear I/O area of the server board between the PS/2 mouse/keyboard stacked connectors and the video/serial stacked connectors. The location of these LEDs is shown in the following figure.

A B

AF000204

A.System ID LED

B.System Status LED

Figure 20. System ID LED and System Status LED Locations

The blue System ID LED can be illuminated using either of the following two mechanisms.

By pressing the System ID button on the system front panel, the ID LED displays a solid blue color until the button is pressed again.

By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED either blinks blue for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI Chassis Identify value is issued to turn it off.

54

Revision 1.7

 

 

Intel order number: D41763-008

Intel® Server Boards S5000PSL and S5000XSL TPS

Intel® Light Guided Diagnostics

The bi-color System Status LED operates as follows:

 

 

 

Table 40. System Status LED

 

 

 

 

 

 

Color

State

Criticality

 

 

Description

 

 

 

 

 

Off

N/A

Not ready

 

AC power off

Green/

Alternating

Not ready

 

Pre DC Power On – 20-30 second BMC Initialization when AC is

Amber

Blink

 

 

applied to the server. Control Panel buttons are disabled until BMC

 

 

 

 

initialization is completed.

Green

Solid on

System OK

 

System booted and ready.

Green

Blink

Degraded

 

System degraded

 

 

 

 

Unable to use all of the installed memory (more than one DIMM

 

 

 

 

 

installed).

 

 

 

 

Correctable errors over a threshold of 10 and migrating to a

 

 

 

 

 

spare DIMM (memory sparing). This indicates that the user no

 

 

 

 

 

longer has spare DIMMs indicating a redundancy lost condition.

 

 

 

 

 

Corresponding DIMM LED should light up.

 

 

 

 

In a mirrored configuration, when memory mirroring takes place

 

 

 

 

 

and system loses memory redundancy. This is not covered by (2).

 

 

 

 

Redundancy loss such as power supply or fan. This does not

 

 

 

 

 

apply to non-redundant subsystems.

 

 

 

 

PCI Express* link errors

 

 

 

 

CPU failure/disabled – if there are two processors and one of

 

 

 

 

 

them fails

 

 

 

 

Fan alarm – Fan failure. Number of operational fans should be

 

 

 

 

 

more than minimum number needed to cool the system

 

 

 

 

Non-critical threshold crossed – Temperature and voltage

 

 

 

 

 

Amber

Blink

Non-critical

 

Non-fatal alarm – system is likely to fail

 

 

 

 

Critical voltage threshold crossed

 

 

 

 

 

VRD hot asserted

 

 

 

 

Minimum number of fans to cool the system are not present or

 

 

 

 

 

have failed

 

 

 

 

In a non-sparing and non-mirroring mode, if the threshold of ten

 

 

 

 

 

correctable errors is crossed within the window.

 

 

 

 

 

Amber

Solid on

Critical, non-

 

Fatal alarm – system has failed or shut down

 

 

recoverable

 

DIMM failure when there is one DIMM present and no good

 

 

 

 

 

memory is present

 

 

 

 

Run-time memory uncorrectable error in non-redundant mode

 

 

 

 

 

IERR signal asserted

 

 

 

 

 

Processor 1 missing

 

 

 

 

Temperature (CPU ThermTrip, memory TempHi, critical

 

 

 

 

 

threshold crossed)

 

 

 

 

No power good – power fault

 

 

 

 

Processor configuration error (for instance, processor stepping

 

 

 

 

 

mismatch)

 

 

 

 

 

 

Revision 1.7