  1. Lime ash dust (w)

Fly ash is also known as influenza ash is a residue produced in the combustion, and includes fine particles that rise with the flu gases. The ash, which does not increase, referred to as bottom ash. In the industrial context, fly ash generally refers to the ashes produced during the combustion of coal. Fly ash is generally captured by electrostatic precipitators or other equipment particle filtration before the flue gases reach the chimneys of power plants, coal-fired, and at the bottom ash removed from the furnace base, in this case, together known as coal ash. Depending on the source and coal burned structure, components of fly ash vary considerably, but all fly ash contains a significant amount of silicon dioxide (of SiO) (and amorphous and transparent) and slaked lime (CEO), both being local ingredients in many coal-bearing strata of rock .

In the production of hydraulic binder used slag mixture of different chemical and mineralogical composition with a high content of SiO2, and therefore its properties and applications is usually regarded with lime-pozzolan binder. However, as the artificial mineral additives, a mixture of ash and slag have a number of differences from the pozzolanic additive due to its high content of A12O3, CaO Fe2O3i, in their composition may not had time to burn from the combustion of the fuel and organic carbon. The presence of CaO is higher than 15% may impart ashes and slags obtained from the combustion of coal, the property exhibit hydraulic activity without introducing into it an alkaline curing activator or sulfate. The presence of these products aluminate and calcium aluminosilicate enhances the binding properties of ash and slag.

Similarly lime-slag binder content tszvesti in the lime-ash binder should be in the range of 15-30%; properties of this binder and scope similar to lime-slag binder.

One of the most active hydration is angry ash from the burning of oil shale - Kukersite containing up to 50% of CaO. Further crushing the ash exhibits pronounced cementing properties, and in the production of shale ash-Portland cement with fly ash content of 20-40% can be obtained cement marks 400, 500 and 600.

  1. Calcined shale (t)

Slate is a bituminous, calcareous shales contain an average of 11-20% organic matter. Other major components are calcium carbonate (about 41%), clay minerals (about 27%) and quartz (about 12%). In Germany, the use of oil shale is concentrated mainly in the north-western slope of the Swabian Alps (region Dotternhausen in Baden-Württemberg) .Goryuchy slate can serve both as a fossil fuel, as well as the clay component in the clinker burning process. When blowing in a special furnace at a temperature of about 800 ° C in a fluidized bed formed by a binder which has a hydraulic or pozzolanic properties. Formed with the heat of combustion is used to generate electricity. In accordance with the composition of the natural starting material containing combustible phase consists of slate klinkeroobrazuyuschih oxides, mainly silicon dioxide (SiO2), in addition it contains small amounts of free calcium oxide (CaO), calcium sulfate, and larger proportions of pozzolanic oxides. Accordingly, in a finely divided state, burned shale must be expressed hydraulic properties as portland cement and pozzolanic calcined shale svoystva.Soglasno requirements should, when tested in accordance with EN 196-1 achieved after 28 days compressive strength of at least 25.0 MPa. The test solutions can be obtained only with finely ground burnt shale cement instead. Samples after preparation of mortar prisms are up to 48 h., Then removed from the mold and stored until testing (testing) of not less than 90% in relative humidity. Degree of stretching (expanding) the calcined slate when tested in accordance with EN 196-3 using a mixture containing 30% of calcined slate with 70% of cement CEM I in accordance with EN 197-1, should be up to 10 mm