Freescale Semiconductor, Inc.

Freescale Semiconductor, Inc.

SERIAL COMMUNICATION INTERFACE (SCI)

6.3.2.1.14SCR SCI Clock Polarity (SCKP) Bit 15

The clock polarity, sourced or received on the clock pin (SCLK), can be inverted using this bit, eliminating the need for an external inverter. When bit 15 equals zero, the clock polarity is positive; when bit 15 equals one, the clock polarity is negative. In the synchronous mode, positive polarity means that the clock is normally positive and transitions negative during data valid; whereas, negative polarity means that the clock is normally negative and transitions positive during valid data. In the asynchronous mode, positive polarity means that the rising edge of the clock occurs in the center of the period that data is valid; negative polarity means that the falling edge of the clock occurs during the center of the period that data is valid. SCKP is cleared on hardware and software reset.

6.3.2.2SCI Status Register (SSR)

The SSR is an 8-bit read-only register used by the DSP CPU to determine the status of the SCI. When the SSR is read onto the internal data bus, the register contents occupy the low-order byte of the data bus and all high-order portions are zero filled. The status bits are described in the following paragraphs.

6.3.2.2.1SSR Transmitter Empty (TRNE) Bit 0

The TRNE flag is set when both the transmit shift register and data register are empty to indicate that there is no data in the transmitter. When TRNE is set, data written to one of the three STX locations or to the STXA will be transferred to the transmit shift register and be the first data transmitted. TRNE is cleared when TDRE is cleared by writing data into the transmit data register (STX) or the transmit data address register (STXA), or when an idle, preamble, or break is transmitted. The purpose of this bit is to indicate that the transmitter is empty; therefore, the data written to STX or STXA will be transmitted next – i.e., there is not a word in the transmit shift register presently being transmitted. This procedure is useful when initiating the transfer of a message (i.e., a string of characters). TRNE is set by the hardware, software, SCI individual, and stop reset.

6.3.2.2.2SSR Transmit Data Register Empty (TDRE) Bit 1

The TDRE bit is set when the SCI transmit data register is empty. When TDRE is set, new data may be written to one of the SCI transmit data registers (STX) or transmit data address register (STXA). TDRE is cleared when the SCI transmit data register is written. TDRE is set by the hardware, software, SCI individual, and stop reset.

In the SCI synchronous mode, when using the internal SCI clock, there is a delay of up to 5.5 serial clock cycles between the time that STX is written until TDRE is set, indicating the data has been transferred from the STX to the transmit shift register. There is a two to four serial clock cycle delay between writing STX and loading the transmit shift register;

6 - 22 PORT C MOTOROLA

For More Information On This Product, Go to: www.freescale.com

Freescale Semiconductor, Inc.

Freescale Semiconductor, Inc.

SERIAL COMMUNICATION INTERFACE (SCI)

in addition, TDRE is set in the middle of transmitting the second bit. When using an external serial transmit clock, if the clock stops, the SCI transmitter stops. TDRE will not be set until the middle of the second bit transmitted after the external clock starts. Gating the external clock off after the first bit has been transmitted will delay TDRE indefinitely.

In the SCI asynchronous mode, the TDRE flag is not set immediately after a word is transferred from the STX or STXA to the transmit shift register nor when the word first begins to be shifted out. TDRE is set two cycles of the 16× clock after the start bit – i.e., two 16× clock cycles into to transmission time of the first data bit.

6.3.2.2.3SSR Receive Data Register Full (RDRF) Bit 2

The RDRF bit is set when a valid character is transferred to the SCI receive data register from the SCI receive shift register. RDRF is cleared when the SCI receive data register is read or by the hardware, software, SCI individual, and stop reset.

6.3.2.2.4SSR Idle Line Flag (IDLE) Bit 3

IDLE is set when 10 (or 11) consecutive ones are received. IDLE is cleared by a start-bit detection. The IDLE status bit represents the status of the receive line. The transition of IDLE from zero to one can cause an IDLE interrupt (ILIE). IDLE is cleared by the hardware, software, SCI individual, and stop reset.

6.3.2.2.5SSR Overrun Error Flag (OR) Bit 4

The OR flag is set when a byte is ready to be transferred from the receive shift register to the receive data register (SRX) that is already full (RDRF=1). The receive shift register data is not transferred to the SRX. The OR flag indicates that character(s) in the receive data stream may have been lost. The only valid data is located in the SRX. OR is cleared when the SCI status register is read, followed by a read of SRX. The OR bit clears the FE and PE bits – i.e., overrun error has higher priority than FE or PE. OR is cleared by the hardware, software, SCI individual, and stop reset.

6.3.2.2.6SSR Parity Error (PE) Bit 5

In the 11-bit asynchronous modes, the PE bit is set when an incorrect parity bit has been detected in the received character. It is set simultaneously with RDRF for the byte which contains the parity error – i.e., when the received word is transferred to the SRX. If PE is set, it does not inhibit further data transfer into the SRX. PE is cleared when the SCI status register is read, followed by a read of SRX. PE is also cleared by the hardware, software,

SCI individual, or stop reset. In the 10-bit asynchronous mode, the 11-bit multidrop mode,